post

The Color Brown

The Color Brown

 

Let’s face it – if our customers agree blue, yellow or red eyebrows, life would be much simpler. No problem, Mrs. Jones, who has only the red of her eyebrows. It will complement the color of the bloodshot eyes, which seem to have all the time and’ll last much longer than the brown color that was used because it is a primary color and the primary colors have a long life. Or, how about a nice yellow color that matches the appearance of jaundice on your skin, Mrs. Smith? No problem. The yellow color disappears faster than red or blue, but for you, yellow eyebrow will be the sun in your life for a long time. Or, we could make a beautiful blue front for you, Mrs. Doe. Now there is a forehead color that is likely to make in his grave, and we always try to harmonize the frontal colors with tonal attributes of the skin, the blue will highlight the dark circles under the eyes like no other color. It’s really beautiful.

Okay, we had our stupid moment and I hope it made you smile. You have to find humor in the dilemma of brown or certainly crazy looking for it. Now, to achieve the true intention of this article is to understand and how to stay away from brown pigments. Most customers want brown eyebrow tones, whether it’s a blonde (lighter shades of brown), light brown (darker than blond), a medium brown or dark brown (some bordering black look.) There are some, but only a few, clients requesting black eyebrows and it is seldom recommended to use black eyebrow procedure properly, unless a black or dark color alone will appear after healing a very dark skin tone. It is rare, but we do not want to operate on the skin tones with absolute respect and customer demands. The dark brown pigments serve the customers eyebrows much better than a straight black because the black law can erase additional blue or gray tones. Correcting the most requested color for eyebrows is one that has gone to an orange, gray or blue hue. It rarely looks green (but not impossible) because of the heat factor of the blood flow in the forehead area and sometimes you will see a pinkish or missing correction eyebrow.

Impact of needle configuration:
When choosing a brown pigment for your customer, as you have heard many times, you have to use your experience and move quickly in your mind the impact of the customer’s skin tone will be in relation to the pigment put on the skin. The pigment plus tone of the skin is equal to a different aspect of the pigment that has placed on the skin. Other factors also influence the neat brown color.

Elizabeth Finch Howell introduced the concept much more that the setting of the needle is small for procedural eyebrows, more ashes (ashes and is always cooler and darker), the healing process will appear. Why? Due to the small needles intersecting the skin more effectively and generally place the deepest pigment. Use of larger needle configurations have less cutting effect and, for lack of a better word, make more or less pigment on the skin, placing the pigment slightly closer to the light and away the direct relationship with blood flow (Blue.) Pigment that stays closest to the surface of the skin will reflect more light and appear less cold than the pigment that lies deepest in the skin.

In theory, if a pin number 1 or 3 is used on the right side of the eyebrow procedure for a client and a number of 5 or 8 on the left side when the procedure is cured, it is possible to see that the right shivering is slightly More cold (ash) and therefore darker than the left. So just before we know whether our choice as a technician is using smaller needle configurations, and if the client wants a hot eyebrow, he will receive compensation for the use of small needles by selecting a slightly higher pigment to the eyebrows .

post

An Introduction to Robot Operating System (ROS)

An Introduction to Robot Operating System (ROS)

 

Developing a robot with a computer brain requires a lot of software tools from the secondary computer software controllers, third-party tools for computer vision and simulation tools. ROS includes all the tools and manages the way to develop a code for your robot.
Instead of reinventing the wheel every time, some admins can help by putting together all these tools and managing the way they develop the code to their robot. ROS (Robot Operating System) is one of these milestones. This is a special framework originally developed by the Stanford IA Laboratory in 2007 for the development of robots. The Open Source Robotic Foundation now maintains ROS.

The ROS concept goes far beyond a border. ROS is an operating system, since it provides all the services offered by other operating systems, such as the acquisition of equipment, control of low level devices, the execution of the most used functions, the passage of messages between processes, and the Package management. Although ROS is still a part that is not an independent operating system or RTOS and is not the only framework for robots, it seems to be widely adopted and have a large community of developers.

ROS can be installed on a single-board computer (SBC) like Raspberry Pi-level and up with Ubuntu / Debian distribution. However, other platforms are supported experimentally or by the community.

 

ROS Logo

 

An overview of how ROS works
Before we delve into and start playing with ROS, we need to see the overall picture of the system.

In general, the ERO is composed of code and tools that help your project code to perform the required work, including the infrastructure to run it, since the messages that pass between processes.

ROS is designed to be a flexible coupling system in which a process is called a node and each node must be responsible for a task. Nodes communicate with each other using messages through logical channels called themes. Each node can send or receive data from the other node using the publication / subscription model. Let’s see this in action later.

The main purpose of ROS is to support the reuse of code in research and development in robotics so that you can find an integrated package system. Again, remember that ROS is not an operating system, a library or RTOS. It is a framework using the concept of an operating system.

post

An Introduction to Oscilloscope Probes

An Introduction to Oscilloscope Probes

 

Speaking oscilloscope probes in general terms …
An oscilloscope (aka scope or O-scope) is a very powerful tool – and probably the most commonly used material – for electrical engineers or anyone who wants to measure the electrical properties of electronic devices. However, it takes more than an oscilloscope; At least one probe is also necessary.

When selecting a sensor for the O-Scope, it is best to check the manual for the O-Scope to see which type of probe is recommended. If the manual is nowhere (which is often the case in the real world), visit the oscilloscope manufacturer’s website for recommendations.

The following information should also be taken into account when choosing probes:

Make sure that the sensor input connector matches the connector of your range.
Most oscilloscopes have BNC connectors; SMA is another possibility. See Figures 1 and 2 below.
Choose a probe with the input resistance and the ability to match the input resistance and the capability of its range. Generally, it is desirable that the probe has the least influence on the measurement loop – this is called the charge effect. Strength and compatibility capability are essential to ensure proper signal transfer and signal accuracy.

 

Most modern areas allow you to select an input resistance of 50 Ω or 1 M. For a general test, a 1 m input is commonly used. A 50 Ω input resistor is used for high speed (microwave feed) signals, The propagation delays in the logic circuits and impedance tests of printed circuit boards.

Unlike standard input resistance with a range of 1 M or 50 Ω, the range of an input capacity may vary depending on the range of the range and other design features. That being said, a common input capacity for many 1 MW tranches is 20 pf. However, this value can range from 100 pF to 5 pF. The best approach, to match a probe with a scope, is to first select a probe whose capability is within range of its range, then adjust the probe’s ability by adjusting its compensation network by Condenser section of the probe, if possible. This process is known as your name probe compensation.

 

How many and what types of probes do you need?
The number of probes and the type of sensors you need depend on the current situation. For example, if only individual DC voltage measurements are required, a 1 M passive voltage probe would be required at one end. However, if you set the time to install and maintain high-speed signals, such as NAND data rows on a hard disk (SSD), you have to use two high-speed active differential probes. See Figure 4 for an example of this type of measurements.